Relighting an automatic pilot light on a gas appliance is a routine maintenance task that can restore hot water or heating without a service call. This guide covers the safe, step-by-step process for most modern gas water heaters and furnaces, including what to do if the pilot won’t stay lit.
What You’ll Need
- A flashlight or headlamp
- A long-reach lighter or a barbecue-style lighter with a flexible neck
- A small adjustable wrench (for some models)
- A soft cloth for cleaning
- Your appliance’s manual (if available)
Step-by-Step
- Turn off the appliance. Locate the gas control valve—typically a round dial with settings like OFF, PILOT, and ON. Turn it to OFF and wait at least five minutes. This allows any lingering gas to dissipate. Do not skip the wait; it prevents a flash fire.
- Locate the pilot assembly. On a water heater, it’s usually behind a small access panel near the bottom. On a furnace, it’s inside the burner compartment. Remove any covers or panels carefully, using a screwdriver if needed.
- Find the pilot tube and thermocouple. The pilot tube is a thin metal tube that ends in a small nozzle. Next to it is the thermocouple—a copper wire with a bulbous tip. These two are the core of the pilot assembly.
- Set the dial to PILOT. On most valves, you’ll press the dial down while in the PILOT position. This opens the gas valve manually so gas flows to the pilot nozzle.
- Press and hold the dial. While holding the dial down, bring your lighter to the pilot nozzle and ignite it. You should see a small blue flame. If it doesn’t light within a few seconds, stop, wait a few minutes, and try again.
- Hold the dial for a full minute. Once the pilot flame is burning, keep the dial pressed down. This heats the thermocouple, which generates a small electric current that keeps the gas valve open. If you release too soon, the pilot will go out.
- Release the dial and check the flame. After about a minute, release the dial. The pilot flame should stay lit. If it goes out, repeat the process, holding a bit longer.
- Turn the dial to ON. With the pilot burning steadily, turn the dial from PILOT to ON. You should hear the main burner ignite shortly after.
- Replace all access panels. Put back any covers you removed, then set the appliance’s thermostat to your desired temperature.
- Verify normal operation. Listen for the burner cycling on and off, and check that the pilot flame remains steady. If the appliance is a water heater, wait a few minutes and feel the pipe near the top for warmth.
Common Mistakes
- Not waiting long enough after turning off the gas. Gas lingers in the combustion chamber. Rushing this step can cause a small explosion or flash fire.
- Releasing the dial too early. The thermocouple needs time to heat up. Releasing after a few seconds will usually cause the pilot to go out.
- Using the wrong lighter. A standard match or a small lighter can burn your fingers. Always use a long-reach lighter.
- Forgetting to turn the dial to ON. If you leave it on PILOT, the main burner won’t fire, and you’ll think something is broken.
- Ignoring the flame color. A yellow or orange flame indicates incomplete combustion, which can produce carbon monoxide. The flame should be blue.
Tips
- Clean the pilot nozzle. If the pilot flame is weak or sputtering, use a can of compressed air to blow out any dust or debris from the nozzle.
- Check the thermocouple. If the pilot lights but won’t stay lit, the thermocouple may be dirty. Gently rub it with fine sandpaper or a soft cloth to remove oxidation.
- Keep the area clear. Remove any flammable materials, such as boxes or cleaning supplies, from around the appliance before you begin.
- Work in good light. Use a flashlight to see the pilot assembly clearly. It’s often in a dark corner.
- Read your manual. Some newer appliances have electronic ignition systems instead of a standing pilot. If your appliance has no pilot dial, it may not be relightable this way.
Troubleshooting
The pilot won’t light at all. First, make sure the gas supply is on. Check the shut-off valve on the gas line—it should be parallel with the pipe. If it’s perpendicular, turn it to open. If gas is on and you still get no flame, the pilot tube may be blocked. Blow through it gently with compressed air.
The pilot lights but goes out when you release the dial. This is almost always a thermocouple issue. The thermocouple may be loose, dirty, or worn out. Tighten the nut that connects it to the gas valve with a small wrench—careful not to overtighten. If that doesn’t work, clean the tip. If the pilot still won’t stay lit, the thermocouple likely needs replacement, which is a simple part available at most hardware stores.
The pilot flame is yellow or orange. This indicates poor combustion, often from a dirty nozzle or insufficient air. Turn everything off, wait, and clean the nozzle. If the flame remains yellow after cleaning, do not use the appliance—call a professional.
The main burner doesn’t ignite. If the pilot stays lit but the main burner won’t fire when you turn the dial to ON, check the thermostat setting. On a water heater, make sure it’s not set to the lowest setting. On a furnace, check that the thermostat is calling for heat.
You smell gas. If you smell gas at any point, stop immediately. Do not light anything, do not flip any electrical switches, and open windows. Leave the building and call your gas company or emergency services from outside.
Frequently Asked Questions
How often should I relight the pilot? A properly functioning pilot should stay lit for months or years. If you’re relighting it frequently, there’s an underlying issue, usually the thermocouple.
Is it safe to relight the pilot myself? Yes, for most people, as long as you follow the steps carefully, especially the wait time after turning off the gas. If you’re uncomfortable or unsure, call a professional.
Why does my pilot keep going out? The most common causes are a faulty thermocouple, a draft blowing out the flame, or a dirty pilot nozzle. Check these in that order.
Can I use a regular lighter? It’s not recommended because your hand will be too close to the flame. Use a long-reach lighter designed for this purpose.
What if my appliance has an electronic ignition? Many newer furnaces and water heaters don’t have a standing pilot. They use a spark igniter or a hot surface igniter. These systems are typically self-igniting and don’t need manual relighting. If they fail, call a professional.
How do I know if the pilot flame is the right size? The flame should be a small, steady blue cone, usually about half an inch to an inch high. If it’s too small or too large, it may not heat the thermocouple properly.