How to Adjust a Gas Log Fireplace Flame

Adjusting the flame on a gas log fireplace lets you control the heat output and the look of the fire, making it taller and more dramatic or shorter and more efficient. Before you start, confirm your fireplace is a vented or vent-free model, as the adjustment method and safety rules differ, and always check the manufacturer’s manual for your specific unit.

What You’ll Need

  • Owner’s manual for your fireplace (or the model number to look it up online)
  • Flat-head screwdriver (for most pilot and valve adjustments)
  • Phillips screwdriver (for some models)
  • Flashlight or work light
  • Gloves (optional, to keep hands clean)
  • Soapy water in a spray bottle (to check for gas leaks, if you loosen any connections)

Step-by-Step

  1. Turn off the fireplace completely. Make sure the unit is off and has cooled down for at least a couple of hours. If the fireplace has a wall switch, remote, or thermostat, turn it to the off position. Also, close the gas supply valve (usually a small lever or knob on the gas line near the fireplace) to stop gas flow entirely.
  2. Locate the control valve. Open the fireplace’s front panel or remove the decorative screen to access the burner area. The control valve is typically a metal box with a knob or dial, often near the pilot assembly. It may have markings like “ON,” “OFF,” and “PILOT.”
  3. Identify the flame adjustment screw. On many valves, there is a small screw or a separate knob labeled “flame height,” “flame adjustment,” or just a picture of a flame. It might be a flat-head screw that you turn with a screwdriver, or a small dial you can turn by hand. If you can’t find it, check the manual—some models require you to adjust a screw on the burner itself, not the valve.
  4. Adjust the flame height (for vented models). For vented gas logs, the flame is usually set at the factory and should not be changed drastically. If your manual allows adjustment, turn the screw or dial counterclockwise to increase the flame, or clockwise to decrease it. Make small turns—about a quarter of a turn at a time—and observe the change.
  5. Adjust the flame height (for vent-free models). Vent-free units often have a more accessible adjustment. Turn the knob or screw the same way, but be aware that vent-free models are designed to burn with a specific flame pattern for safety. Do not make the flame so high that it touches the logs or the top of the fireplace, as this can cause soot or carbon monoxide issues.
  6. Re-light the pilot and test. After adjusting, turn the gas supply back on, follow the lighting instructions on the valve (usually push the knob down, turn to “PILOT,” press the igniter, hold for a few seconds, then turn to “ON”), and light the main burner. Watch the flame for a few minutes.
  7. Fine-tune the flame. If the flame is too low, it may not ignite the logs properly or may produce a weak, blue flame. If it’s too high, it may create soot or make the room too hot. Make further small adjustments, waiting a few minutes between each, until the flame looks even and steady—usually blue at the base and yellow/orange at the tips.
  8. Check for any gas leaks. If you loosened any connections during the process, apply the soapy water solution to the joints and look for bubbles. If you see bubbles, tighten the connection and re-check. If bubbles persist, turn off the gas and call a professional.
  9. Replace the panel and clean up. Once you’re satisfied with the flame, put the front panel or screen back on, and clean up any tools or debris.

Common Mistakes

  • Adjusting while the fireplace is hot. You can burn yourself or damage the valve. Always let it cool completely.
  • Turning the screw too far. This can cause the pilot to go out or the burner to produce a dangerous flame. Use small increments.
  • Ignoring the manual. Some models have specific adjustment procedures, and using the wrong screw can break the valve.
  • Setting the flame too high on vent-free units. This can lead to soot buildup on your logs and walls, and may increase carbon monoxide risk in a poorly ventilated room.
  • Forgetting to check for leaks. Even a small leak is a serious hazard. Always test any connection you touched.

Tips

  • If your fireplace has a remote or thermostat, the flame height may be controlled electronically—check the remote’s settings before touching the valve.
  • For a more realistic look, aim for a flame that licks the bottom of the logs but doesn’t engulf them. This usually means a moderate height.
  • Clean the burner and logs regularly (at least once a year) to ensure proper gas flow and an even flame. Dust and debris can cause uneven burning.
  • If you have a vented fireplace, remember that the chimney must be open and unobstructed. A blocked chimney can cause the flame to burn poorly.
  • Consider having a professional inspect your fireplace annually, especially if you notice any unusual flame color or odor.

Troubleshooting

Flame won’t adjust. If turning the screw does nothing, the valve may be faulty or the screw may be stripped. Try turning it in the opposite direction to see if it was already at the maximum. If it’s stuck, do not force it—call a technician.

Pilot light goes out after adjustment. You may have turned the pilot adjustment screw instead of the main burner screw. Check the manual to confirm which screw is which. If the pilot flame is too low, it won’t stay lit. Adjust the pilot screw slightly to increase the pilot flame, then re-light.

Flame is yellow and sooty. This usually means the air mixture is off, not the height. Look for an air shutter on the burner tube—opening it slightly (turning it to allow more air) will make the flame bluer and cleaner. If you can’t find it, consult the manual or a professional.

Gas smell after adjusting. Immediately turn off the gas supply and ventilate the room. Do not light any flames or switches. Call a qualified technician to inspect the system before using it again.

Flame is too blue and small. This often happens if the gas pressure is low or the air shutter is open too much. Check the gas valve is fully open, and adjust the air shutter to reduce air intake slightly.

Frequently Asked Questions

Q: Can I adjust the flame on any gas log fireplace?
A: Most models have some adjustment, but vented units are often factory-set and may not have an accessible screw. Check your manual first.

Q: Will adjusting the flame affect my gas bill?
A: Yes, a higher flame uses more gas. Lowering the flame can reduce fuel consumption, but always keep it within the manufacturer’s recommended range.

Q: Is it safe to adjust the flame myself?
A: If you follow the manual and take safety precautions, yes. However, if you are unsure or smell gas, stop and call a professional.

Q: How do I know if the flame is too high?
A: If the flame touches the logs or the top of the firebox, or if you see soot forming on the glass or logs, it’s too high. The flame should be stable and not lift off the burner.

Q: What is the difference between the pilot flame and the main flame?
A: The pilot is a small, constant flame that ignites the main burner. The main flame is the large fire you see. Adjusting the main flame height is separate from the pilot adjustment.

Q: Do I need to turn off the gas to adjust the flame?
A: Yes, always turn off the gas and let the unit cool before opening the panel or touching any screws. This prevents accidents and damage.