How to Clean a Screen Well Pump

Cleaning a screen well pump restores water flow and pressure by removing the sand, silt, and mineral buildup that clog the pump’s intake screen. This guide covers the safe, step-by-step process for a typical submersible or jet pump with a screened intake, plus what to do if things go wrong.

What You’ll Need

  • Adjustable wrench or pliers
  • Screwdrivers (flathead and Phillips)
  • Wire brush or stiff nylon brush
  • Mild dish soap or a non-abrasive cleaner
  • Clean bucket or tub
  • Garden hose or access to clean water
  • Replacement screen or filter (if the old one is damaged)
  • Thread seal tape (for reconnecting fittings)
  • Safety glasses and work gloves

Step-by-Step

  1. Turn off power to the pump. Locate the circuit breaker or disconnect switch that feeds the pump and switch it off. If the pump has a control box, also unplug it or switch off its dedicated breaker. This prevents the pump from starting while you work.
  2. Shut off the water supply. Close the main valve between the well and your house, or the valve on the drop pipe if there is one. This stops water from flowing back while you remove the pump.
  3. Relieve pressure. Open a faucet inside the house to drain any remaining water from the pipes. This also releases pressure in the system, making removal safer.
  4. Remove the pump from the well. For a submersible pump, you will need to pull the drop pipe and pump assembly out of the well casing. This usually requires a hoist or a couple of strong helpers. For a jet pump located above ground, disconnect the suction pipe from the well casing.
  5. Locate the screen. The screen is the cylindrical, mesh-covered section at the intake end of the pump or at the bottom of the suction pipe. It may be a separate part or integrated into the pump housing.
  6. Remove the screen. Depending on the design, the screen may be held by screws, a retaining ring, or a threaded collar. Use the appropriate screwdriver or wrench to detach it. If it is glued or press-fit, gently pry it off with a flathead screwdriver, taking care not to bend the mesh.
  7. Clean the screen. Rinse the screen under running water to remove loose debris. Then, using a wire brush or stiff nylon brush, scrub both the inside and outside of the mesh to dislodge sand, scale, and biofilm. For stubborn mineral deposits, soak the screen in a solution of mild dish soap and warm water for a few hours, then scrub again. Avoid harsh chemicals that could damage the mesh or leave residues.
  8. Clean the pump intake. While the screen is off, inspect the intake opening on the pump. Use a small brush or a cloth to wipe away any debris that may have passed through. Do not insert tools too deeply, as you could damage internal impellers.
  9. Rinse all parts. Rinse the screen and the pump intake area with clean water to remove any soap or loosened dirt.
  10. Reinstall the screen. Once everything is clean and dry, reattach the screen. If it uses screws, tighten them evenly. If it threads on, wrap the threads with thread seal tape before screwing it back on. Ensure the screen is seated snugly to prevent leaks.
  11. Reinstall the pump. Carefully lower the pump back into the well, or reconnect the suction pipe for a jet pump. Make sure all connections are tight and secure.
  12. Turn the water supply back on. Open the main valve slowly to allow the system to refill. Check for leaks around the pump and screen connections.
  13. Restore power. After confirming there are no leaks, turn the circuit breaker back on. Run the pump for a few minutes to verify normal flow and pressure.

Common Mistakes

  • Forgetting to turn off power. Working on a live pump is extremely dangerous. Always double-check that the breaker is off and tag it so no one else flips it on.
  • Not relieving pressure. If you skip opening a faucet, water may spray out when you disconnect the pump, causing a mess and potential water damage.
  • Using harsh chemicals. Strong acids or bleach can corrode the screen and contaminate your water supply. Stick to mild soap and water.
  • Scrubbing too aggressively. A wire brush can tear the mesh if you press too hard. Use a gentle touch, especially on finer screens.
  • Reinstalling a damaged screen. If the screen has holes or tears, it will let sand into the pump, causing premature wear. Replace it if you see any damage.
  • Overtightening connections. Cracking a fitting or stripping threads can cause leaks. Tighten firmly, but do not force.

Tips

  • Keep a spare screen on hand. They are inexpensive and can save you from a second trip to the store.
  • If your well has a lot of sand, consider installing a sediment filter at the point of use to protect fixtures.
  • Clean the screen at least once a year, or more often if you notice a drop in water pressure.
  • Take a photo of the pump and screen before disassembly to help you remember how to put it back together.
  • Lubricate O-rings with a silicone-based lubricant to ensure a good seal.
  • If you are not comfortable pulling the pump, hire a licensed well contractor—it is a physically demanding job.

Troubleshooting

  • Water flow is still low after cleaning. The screen may not be the only issue. Check the pressure tank, the pressure switch, and the drop pipe for leaks or blockages. Also, verify that the well itself has sufficient water—a dry well can cause low pressure.
  • Pump runs but does not deliver water. This could indicate a broken drop pipe, a failed check valve, or the pump is air-locked. Try priming the pump if it is a jet pump. For submersibles, check the wiring and the control box.
  • Water is still sandy after cleaning. The screen may be damaged, or the well casing may have a breach. Replace the screen first; if the problem persists, have the well inspected by a professional.
  • Leak at the screen connection. Remove the screen, apply fresh thread seal tape, and re-tighten. If the threads are stripped, you may need to replace the fitting.
  • Pump trips the breaker immediately. This often indicates a short circuit or a seized motor. Turn off the power and call a professional—do not attempt to repair electrical components yourself.
  • You cannot pull the pump out. If the drop pipe is stuck, do not force it. You may need a well puller or professional assistance to avoid damaging the casing.

Frequently Asked Questions

How often should I clean my well pump screen?
Most experts recommend cleaning the screen once a year as part of routine well maintenance. If you have a sandy well or notice a gradual drop in pressure, clean it more frequently.

Can I clean the screen without pulling the pump?
For submersible pumps, you generally must pull the pump out of the well to access the screen. For jet pumps, the screen is often on the end of the suction pipe, which you can pull up without removing the entire pump.

What is the best way to remove mineral scale from the screen?
A soak in a mild vinegar or citric acid solution can help dissolve scale, but always rinse thoroughly afterward. Avoid strong acids that can damage the metal.

How do I know if the screen needs to be replaced?
If you see holes, tears, or severe corrosion, replace it. Also, if the mesh is so clogged that cleaning does not restore flow, a new screen is a safer bet.

Can I use bleach to disinfect the screen?
Bleach can be used for sanitizing, but it must be diluted and rinsed extremely well. It is generally safer to use a food-grade sanitizer if you are concerned about bacteria. Always follow local health guidelines for well disinfection.

What should I do if my pump still has problems after cleaning?
If cleaning the screen does not resolve the issue, the problem may lie with the pump motor, pressure switch, or the well itself. Contact a licensed well contractor for a full inspection.